SW120 Technical Information
Application |
Interrupted Uninterrupted |
|
Thermal Current Rating |
125A |
125A |
Intermittent Current Rating: |
||
30% Duty |
210A |
210A |
40% Duty |
190A |
190A |
50% Duty |
170A |
170A |
60% Duty |
150A |
150A |
70% Duty |
140A |
140A |
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:(In accordance with UL583*) |
||
Blowouts |
- |
|
No Blowouts |
1000A at 80V D.C. |
|
Rated Fault Current Breaking Capacity (Icn) Resistive Load:(In accordance with UL508*) |
||
Blowouts |
- |
|
No Blowouts |
- |
|
Maximum Recommended Contact Voltages |
||
Blowouts |
- |
- |
No Blowouts |
80V |
96V |
Typical Voltage Drop per pole across New Contacts at 100A |
40mV |
|
|
||
Mechanical Durability |
> 3,000,000 Cycles |
|
Coil Voltage Available (Us) (Rectifier board required for A.C.) |
6 - 240V |